Transformers power industries, grids, and critical infrastructures, and their reliability depends on precise, standards-driven evaluation. At TAQQA AL JOHAD, we deliver transformer testing services that strictly follow IEC-approved procedures, ensuring every result is accurate, traceable, and trusted across the power sector.
Our testing environment is built around advanced diagnostic technology, controlled laboratory conditions, and expert engineers who understand transformer behavior down to the smallest detail. From early fault detection to performance benchmarking, TAQQA AL JOHAD helps clients maintain operational continuity, reduce risks, and extend the life of their assets with confidence.
TAQA AL JOHAD is an independent company that provides professional local third-party inspection, testing, certification, and calibration. This state-of-the-art facility plays a pivotal role in ensuring the highest quality, reliability, and performance of transformers.
Breakdown Voltage (IEC 60156)
Dissipation Factor (IEC 60247)
Resistivity @ 90°C (IEC 60247)
Power Factor @ 25°C (ASTM D924)
Power Factor @ 100°C (ASTM D924)
Water Content (IEC 60814)
Density @ RT (ASTM D4502)
Viscosity @ 40°C (ASTM D445)
Viscosity @ 100°C (ASTM D445)
Viscosity Index (ASTM D445)
Flash Point (ASTM D3828)
Pour Point (ASTM D97)
Color (ASTM D1500)
Appearance (ASTM D1524)
TAN / Acidity (IEC 60296)
Oxidation Stability (IEC 61125)
Total Sulfur (ASTM D4294)
Oil Quality Index Calculation
pH Value (ASTM 7946)
Antioxidant (BHT) (ASTM D4768)
DGA (IEC 60567 / ASTM D3612C HS)
Furan (IEC 61198)
Degree of Polymerization Calculation
Paper Sample DP Value (IEC 60450)
Particle Count NAS 1638
Sediment & Soluble Sludge (ASTM D1883)
Metals (ASTM D5185)
Polychlorinated Biphenyls (PCBs) (ASTM D4059)
Potentially Corrosive Sulfur (CCD) (IEC 62535)
Dibenzyl Disulfide (DBDS) (IEC 62697-1)
Corrosion Copper Strip Test (ASTM D1275b)
Carbon Types Composition (ASTM D2140 / IEC 60590)
Oil IR Spectra (ASTM D2668)
Oil Quality Index Calculation
Other Specialized Analysis as Required
Insulation diagnostic of transformer windings
Assessment of winding resistance and connection condition.
Verification of turns ratio and vector-group configuration.
Evaluation of winding insulation condition.
Assessment of bushing insulation condition
Measurement of excitation current characteristics.
Assessment of transformer impedance characteristics at
reduced test current
Testing of current transformer performance.
Measurement of excitation current characteristics.
Assessment of magnetic balance across transformer phases.
Comparison of frequency-response characteristics with the
transformer fingerprint.
Verification of core/frame insulation condition
Verification of tap changer operating functionality.
Testing of transformer control-panel signals.
Verification of pressure integrity and leakage condition.
Testing and commissioning of the RTCC panel and AVR
system.
Backed by years of industry experience, TAQQA AL JOHAD combines technical capability with deep sector knowledge to provide IEC-aligned transformer assessment. Our experts evaluate transformers under simulated real-world conditions, applying strict international methodologies to uncover hidden issues long before they impact your operations. Whether it’s routine quality checks, pre-commissioning validation, or health diagnostics for aging transformers, we follow a systematic, data-driven approach that guarantees dependable results and clear decision support. Our dedicated, experienced technical team performs for all types of tests in line with IEC.
Backed by years of industry experience, TAQQA AL JOHAD combines technical capability with deep sector knowledge to provide IEC-aligned transformer assessment. Our experts evaluate transformers under simulated real-world conditions, applying strict international methodologies to uncover hidden issues long before they impact your operations. Whether it’s routine quality checks, pre-commissioning validation, or health diagnostics for aging transformers, we follow a systematic, data-driven approach that guarantees dependable results and clear decision support. Our dedicated, experienced technical team performs for all types of tests in line with IEC.
Ideally, once a year, but high-load, mission-critical, or aging units may require more frequent assessments.
At TAQQA AL JOHAD, we blend technical precision with industry-driven solutions to protect your equipment, reduce operational risk, and ensure sustained performance.
Special tests for transformers are conducted in addition to routine tests, usually to assess specific performance characteristics, ensure compliance with customer requirements, or diagnose potential issues. These tests are not mandatory for all transformers but are often required for critical applications.
These tests help verify the transformer’s design, safety, and operational performance. Let me know if you need more details on any specific test!
Routine tests for transformers are standard tests performed to verify the quality, performance, and safety of the transformer before it is put into operation. These tests ensure that the transformer meets design specifications and regulatory standards. Below are the key routine tests conducted on transformers:
1. Insulation resistance test (Megger test)
2. Winding resistance test
3. Ratio Test (Turn ratio test)
4. Polarity and Phase Relation Test
5. Short-Circuit Test (Impedance Test)
6. No-Load Loss and Current Test
7. Dielectric Tests (High Voltage Tests)
8. Leakage Test (Oil Leakage Test)
9. Magnetic Balance Test
10. Functional Tests of Protection and Control Equipment
These routine tests ensure the transformer operates reliably and safely in service. Let me know if you need more details on any specific test!
Special tests for transformers are conducted in addition to routine tests, usually to assess specific performance characteristics, ensure compliance with customer requirements, or diagnose potential issues. These tests are not mandatory for all transformers but are often required for critical applications. Below are the key special tests performed on transformers:
1. Lightning Impulse Test
2. Switching Impulse Test
3. Temperature Rise Test
4. Short-Circuit Test (Dynamic Ability Test)
5. Partial Discharge Test
6. Noise Level Test
7. Harmonic Analysis of No-Load Current
8. Zero Sequence Impedance Test
9. Tank Pressure Test
10. Insulation Oil Tests
11. Measurement of Stray Losses
12. Overload Test
Special tests are typically performed based on customer requirements, standards (IEC, IEEE, IS, etc.), and operational needs. Let me know if you need further details on any test!
Special tests for transformers are conducted in addition to routine tests, usually to assess specific performance characteristics, ensure compliance with customer requirements, or diagnose potential issues. These tests are not mandatory for all transformers but are often required for critical applications. Below are the key special tests performed on transformers:
1. Lightning Impulse Test
2. Switching Impulse Test
3. Temperature Rise Test
4. Short-Circuit Test (Dynamic Ability Test)
5. Partial Discharge Test
6. Noise Level Test
7. Harmonic Analysis of No-Load Current
8. Zero Sequence Impedance Test
9. Tank Pressure Test
10. Insulation Oil Tests
11. Measurement of Stray Losses
12. Overload Test
Special tests are typically performed based on customer requirements, standards (IEC, IEEE, IS, etc.), and operational needs. Let me know if you need further details on any test!
Taqa Al Johad is a leading provider of Transformer Repair and Maintenance services, catering to a diverse range of clients across various locations in Saudi Arabia. Our service offerings include Maintenance Contracts, Installation, Erection, Testing & Commissioning of transformers.